Finish-thompson SP22 Series Self-Priming Manual de usuario Pagina 1

Busca en linea o descarga Manual de usuario para Zapatillas Finish-thompson SP22 Series Self-Priming. Finish Thompson SP22 Series Self-Priming User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Operation Manual

Assembly, Installation and Operation Manual Literature ID No. FT08-1024GSP22 Series Self-Priming Pumps

Pagina 2 - TABLE OF CONTENTS

10 Applying equal pressure, gently pry both screwdrivers in upward motion away from the table (to avoid damaging sealing surface). See figure 12

Pagina 3 - Chemical Reaction Disclaimer

11To separate impeller (item 7A, 7) from the inner drive (item 8A, 8), use two flat head screwdrivers in slots provided to gently pry apart. Reasse

Pagina 4

12 evenly until the prongs snap onto the surface of the inner volute. See figure 29. WARNING: Magnetic force hazard. Keep fingers away from mating

Pagina 5 - • Priming Time

13SP22 PART NUMBER EXPLANATIONNOTE: Pump end includes wetted components, drive magnet and motor adapter. The wet end includes wetted components only.

Pagina 6 - 132 B5 = M12 x 1.75

142518266A12B13BSP22 PARTS DIAGRAM2A2567A488A910111213A1422A151719713202123241614A1312A226B

Pagina 7 - Section II - Installation

15SP22 Spare Parts ListItem Qty Description Polypropylene PVDF1 1HousingNPT threads 106437 106437-1BSP threads 106437-2 106437-3Fiberglass flanges 2&qu

Pagina 8 - Section IV - Shutdown

16SP22 Spare Parts - continuedItem Qty Description Polypropylene PVDF6A 1Volute / Barrier Seal - 16-1/8” lengthFKM107458EPDM107458-16B 1Volute / Barri

Pagina 9 - Section V - Disassembly

17SP22 Spare Parts - continuedItem Qty Description Polypropylene PVDF13B 2Set Screws NEMA frames only J10108414 1Motor Adapter Flange 213/215TC 106775

Pagina 10

18SP22 Impeller AssembliesThrust RingImpeller Material#1 #1A #1B #1C #2 #2A #2B #2C #3 #3A7.00" 6.88" 6.75" 6.63" 6.50" 6.38&

Pagina 11

19Tech Service 1-800-888-3743Literature ID No. FT08-1024GPart Number 106783, R13, 6-4-13Section VI - TroubleshootingGeneral Notes:• Cold water will

Pagina 12

2TABLE OF CONTENTSImportant Notice .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. .

Pagina 13

3Chemical Reaction DisclaimerThe user must exercise primary responsibility in selecting the product’s materials of construction, which are compatible

Pagina 14 - SP22 PARTS DIAGRAM

4CAUTION: Never start or operate with a closed suction valve. WARNING: Operation without priming or against a closed discharge valve can result in hig

Pagina 15 - SP22 Spare Parts List

5• Priming Liquid Volume Initial filling (or refilling after maintenance) of the pump housing requires (2 1/2) US gallons (9.5 liters) of liquid.• Pr

Pagina 16

6SP22 Assembly, Installation and OperationUnpacking and InspectionUnpack the pump and examine for any signs of shipping damage. If damage is detected

Pagina 17 - HARDWARE - ALL SP22 MODELS

7 NOTE: The clearance between the motor adapter and drive magnet is tight (about .010”/.254 mm).5. Install the pump end on the motor/drive magnet

Pagina 18 - SP22 Impeller Assemblies

8CAUTION: Do not operate the pump to check rotation until the pump is full of liquid.Check all electrical connections with the wiring diagram on

Pagina 19 - Section VI - Troubleshooting

9MaintenanceRecommended maintenance scheduleThe recommended maintenance schedule depends upon the nature of the fluid being pumped and the specific appl

Comentarios a estos manuales

Sin comentarios